The National Construction Code (NCC) is the benchmark for building safety in Australia. It sets out minimum requirements for structure, fire safety, access and egress as part of its performance requirements. Rather than only applying fixed rules, the NCC allows designers to use performance-based approaches where they provide evidence and analysis showing a building achieves the same or better safety outcomes. Fire safety engineers calculate potential evacuation times and compare them with acceptable safety thresholds to demonstrate that egress systems are sufficient for the expected number of occupants and the building’s specific layout. Performance solutions are particularly important in buildings with unique designs where prescriptive measures alone are not suitable.
Australia has released the 2025 edition of the NCC for industry preview ahead of formal adoption by states and territories in 2026. This new edition has a range of updates across technical areas including fire safety and the way performance solutions are documented and verified. One significant change is the removal of the “expert judgement” assessment method for fire safety performance solutions. Previously fire engineers could use expert judgement as one way to show compliance with performance requirements, but under the new approach designers must now use clearer and more structured assessment methods. The intention of this change is to improve the robustness and transparency of performance solutions so that life safety outcomes are better evidenced and less open to subjective interpretation. This affects how engineers justify egress design and other fire safety measures in their reports and submissions.
Another related update under discussion prior to finalisation involves fire-isolated exits and how occupants are informed about the way these exits operate. Fire-isolated exits are protected escape routes such as internal stairways intended to remain tenable during a fire. Proposed changes in the draft code include clearer provisions for signage and occupant information on levels where re-entry into the building is not possible from a fire-isolated exit. The aim is to reduce the risk of confusion if an occupant reaches a protected stair but cannot return to the floor they started from after using that exit.
These updates sit alongside broader industry efforts to improve safety and inclusivity. Fire safety professionals increasingly consider inclusive egress design, looking at how evacuation strategies affect people with mobility limitations, sensory impairments or other vulnerabilities. Workshops and forums bring together designers, fire engineers and emergency planners to discuss how standard egress provisions might be adapted or supplemented so all occupants can reach safety under a range of emergency conditions.
Fahrenheit Global fire safety engineers boast a wide range of credentials and specialise in accessibility and egress. To learn more about our services and how they can support the safety of your project please contact us here.